Key takeaways
- Backing rod controls sealant depth and helps prevent three-sided adhesion.
- Choose foam type and size to suit joint width, moisture exposure and sealant requirements.
- Correct joint depth helps control sealant consumption.
- Use compatible bond breaker tape where a joint is too shallow for foam.
Backing rod is a compressible foam inserted into a joint before you apply sealant. It controls how deep the sealant sits, supports it during application and helps it accommodate movement without tearing or pulling away from the surrounding surfaces.
If you're sealing a deep gap between concrete panels, around a window frame or between two construction materials, backing rod can be just as important as the sealant itself.

Why filling the entire gap with sealant isn't always a good idea
It might seem logical to fill a deep joint completely with sealant. After all, more material should create a stronger seal.
In a movement joint, however, using more sealant than necessary can work against you.
Building materials expand, contract and move independently as temperatures change and structures experience loads. The sealant between them needs to accommodate that movement while remaining bonded to the sides of the joint.
If the sealant also sticks to the bottom of the joint, its ability to deform becomes restricted. This is known as three-sided adhesion and can contribute to splitting or adhesion failure.
Backing rod helps prevent this by separating the sealant from the bottom of the joint. It also allows you to control the amount of sealant you apply.
Getting the sealant depth right
The shape of a sealant joint influences how it behaves during movement.
A round backing rod helps create a sealant profile that is thinner through the centre while maintaining contact with the joint faces. This allows the sealant to deform more effectively as the joint opens and closes.
Many construction sealants use a width-to-depth ratio of approximately 2:1, although minimum and maximum depths vary between products.
For example, a 20 mm wide joint designed around a 2:1 ratio would have a nominal sealant depth of 10 mm.
That doesn't mean every 20 mm joint should be sealed this way. The required dimensions depend on the sealant, expected movement and application.
Establish the sealant depth before selecting and positioning your backing rod.
Open-cell or closed-cell backing rod?
The two common types of backing rod differ in how their foam is constructed. That difference influences how they handle moisture, compression and installation.
Closed-cell backing rod
Adheseal closed-cell backing rod is made from polyethylene foam with enclosed cells that limit water absorption.
It is particularly useful in suitable horizontal joints where moisture exposure is a concern, including concrete slab joints.
Take care when inserting closed-cell foam. Puncturing or damaging its outer surface can release gas and contribute to bubbling in the sealant.
Open-cell backing rod
Adheseal open-cell backing rod is made from breathable polyurethane foam.
It compresses readily, making it useful where joint widths vary. Its permeable structure can also assist the curing of compatible sealants.
Where water can collect in a horizontal joint, consider closed-cell foam instead, subject to the sealant system's requirements.
For a more detailed comparison, see our guide to open-cell versus closed-cell backing rod.
What size backing rod do you need?
Start by measuring the actual width of your joint at several points.
Backing rod needs to be larger than the opening so that it compresses against the sides and stays in position while you apply sealant. A rod that is too small can move deeper into the gap, leaving you with inconsistent sealant depths.
Choosing an excessively large rod can also make installation unnecessarily difficult.
Use the sizing guidance for your chosen foam profile, particularly where joint widths vary significantly.
Round and square profiles are available to suit different joint geometries.
Does backing rod save sealant?
Yes. By controlling the depth of the sealant, backing rod reduces the amount of material needed to fill a deep joint.
For a simple illustration, consider a 20 mm wide joint over a length of one metre:
| Nominal sealant depth | Approximate sealant volume |
|---|---|
| 10 mm | 200 mL |
| 20 mm | 400 mL |
| 30 mm | 600 mL |
These figures assume a rectangular cross-section. Actual consumption varies with the finished joint profile and application wastage.
The objective isn't simply to use less sealant. It's to use the correct amount. Over a large commercial project, getting the joint depth right can also make a substantial difference to material requirements.
What if the joint is too shallow for backing rod?
Where there isn't enough depth to accommodate foam, compatible bond breaker tape can sometimes provide the separation needed to prevent adhesion to the bottom of the joint.
Unlike backing rod, the tape doesn't provide substantial depth control. Its role is to prevent unwanted adhesion.
Specialised joints, including fire-resisting systems and continuously immersed applications, require backing materials selected for the complete system. Ordinary construction backing rod is not automatically suitable for these applications.
Before you start sealing
Prepare the joint faces according to your sealant's requirements before inserting the backing rod. Position the foam at a consistent depth without stretching it excessively, and take care not to damage the surrounding surfaces or foam.
A suitable backing rod insertion tool can make maintaining a consistent depth easier, particularly when working across long runs of construction joints.
For help selecting the sealant itself, read our guide to silicone, polyurethane and hybrid sealants. For tiled bathrooms, see our guide to silicone and grout movement joints.
Products to use
Once you've measured your joint and established the required sealant depth, explore Adheseal's open-cell and closed-cell backing rods to find a suitable profile and size for your job.
Explore Backing RodRelated collections
Related articles
- Silicone or Grout? Understanding Movement Joints in Tiled Bathrooms
- Open Cell vs Closed Cell Backing Rod: Which Should You Use?
- Silicone vs Polyurethane vs Hybrid Sealants: Which Should You Choose?
- PU15 vs PU25 vs PU50: Choosing a Polyurethane Sealant
- Why Bathroom Silicone Fails: Mould, Peeling and Split Joints Explained
- How to Remove and Replace Bathroom Silicone