Potential Outcome: Extended cure times, blistering or loss of adhesion.
Best Practice: For residual moisture >80% RH (ASTM F2170) or ~5% MC (ASTM F2659), prime with Gripset E60 prior to Gripset 51. Verify moisture, then proceed with two-coat system at 750 µm WFT per coat.
Potential Outcome: Pinholing, weak points at corners/penetrations and water ingress.
Best Practice: Gauge every coat with a wet-film comb to 750 µm. Pre-detail all joints, corners and penetrations with Elastoproof B50 Joint Band/Collars or BRW PF Tape, or form fillets with RLA MAX SMP 25.
Potential Outcome: Surface crazing with prolonged UV.
Best Practice: Limit to below-ground/external covered applications or overcoat/cover as per project design. Do not use as a trafficable or finished surface.
Deliver a durable, flexible membrane on a new concrete retaining wall, with reliable adhesion, compliant detailing and clear QA targets before backfilling.
Prepare substrate; cure concrete 28 days and make sound/clean. Prime porous concrete with Gripset 51 (1:3 water). Detail all junctions with Elastoproof B50 and Collars. Apply two coats Gripset 51 at 750 µm WFT each (target 1.0 mm DFT total, ~1.5 L/m²). Recoat after 2–4 h. Backfill after 5 days; full cure 10 days.
Run wet-film gauge checks every 10–15 m² and after breaks. Stagger coat directions (vertical then horizontal) for uniform coverage.
Control costs and avoid rework by waterproofing blockwork planters that have variable porosity and movement at floor/wall junctions.
Prime porous masonry (1:3). Form 25–35 mm coved fillets using Gripset 51-mortar (1:1 with 3:1 sand:cement) at junctions. Detail with Elastoproof B50. Apply two coats at 750 µm WFT. Allow 10 days cure before sustained moisture exposure.
Use the low-build blend (3:1 Gripset 51:mortar) as a base pass in cool conditions to aid drying and improve coverage efficiency on porous blockwork.
Restore failed aged bitumen coatings without full strip-out, ensuring immediate adhesion and flexible bridging over hairline cracking.
Clean thoroughly; remove loose/unsound material. Prime per substrate (often 1:1 on non-absorbent). Seal cracks ≥1–6 mm with RLA MAX SMP 25 and reinforce with Elastoproof B50 or BRW PF Tape. Apply Gripset 51 in two coats at 750 µm WFT each.
Stitch-roll tapes from the centre out to expel air. Do not finish as an exposed, trafficable surface; over-cover as per project design.
No. Gripset 51 is designed for below-ground and covered external use. Long-term UV exposure may cause surface crazing. For exposed areas, overcoat or protect with a suitable finish.
Apply a minimum of two coats at 750 µm wet film thickness (WFT) each, achieving a total dry film thickness (DFT) of 1.0 mm. Always verify using a wet film gauge during application.
For porous surfaces, dilute Gripset 51 1:3 with water. For non-porous surfaces, dilute Gripset 51 1:1 with water or use Gripset OP Primer. For damp/rising damp conditions, use Gripset E60.
Yes. For high build, mix Gripset 51 with mortar at 1:1 ratio. For low build, mix at 3:1 (Gripset 51:mortar). This enhances filling properties and can accelerate drying in cooler conditions.
Yes. It is solvent-free, non-toxic, and non-flammable. Always ensure adequate ventilation during application and curing, especially in enclosed spaces.
No. Gripset 51 is not designed to be finished directly with tiles, renders, screeds, or paints. Apply a compatible over-surface system as per project specifications.
Application / Use Case | Key Benefit | Primary Trades |
---|---|---|
Retaining walls & underground surfaces | Provides a flexible, crack-bridging membrane that resists continuous damp conditions and protects against water ingress. | Waterproofers, Builders |
External cellar & basement walls | Forms a continuous 1.0 mm DFT barrier for long-term moisture protection in subterranean environments. | Waterproofers, Builders |
Planter boxes & garden beds (external) | Resists root moisture penetration; compatible with mortar fillets for wall/floor junctions. | Builders, Landscapers |
Gutter repairs | Adheres to aged bitumen/asphalt for efficient remedial sealing without full strip-out. | Roofers, Maintenance Contractors |
Protective coating on metal/timber | Prevents corrosion, rot and salt damp, extending service life of exposed building components. | Builders, Carpenters, Asset Maintenance |
Repairs to aged asphalt/bitumen coatings | Restores integrity and extends lifespan of existing waterproofing systems. | Remedial Specialists, Maintenance Contractors |
Substrates must be clean, sound, smooth and dry; free from dust, oil/grease, wax, laitance, curing agents, release agents, moss/algae, loose coatings and sharp protrusions. Concrete must cure ≥28 days; cement render/screeds ≥7 days. Patch voids, pitting and non-structural cracks with compatible repair mortars.
Grind, shot-blast or abrade to remove weak layers and contaminants; vacuum thoroughly.
Degrease where required, rinse, then allow to dry. Ensure no standing water before priming.
Prime the entire application area before membrane installation.
Dilute Gripset 51 at 1:3 (v/v) with clean water; mix to a smooth, homogeneous consistency. Apply liberally by brush/roller.
Dilute Gripset 51 at 1:1 (v/v) with water and apply, or use Gripset OP Primer as an alternative.
Apply Gripset E60 at 1–2 coats (≈1 L/3 m² per coat) over mineral substrates with residual moisture or subject to rising damp.
Pre-detail all joints, junctions, movement zones, penetrations, drains and cracks before field coating.
Option A: Embed Elastoproof B50 Joint Band into a wet coat of Gripset 51, then fully encapsulate. Corners: use prefabricated Elastoproof corners.
Option B: Apply BRW PF Tape centrally over joints; roll firmly to expel air and creases.
Option C: Tool a continuous fillet using RLA MAX SMP 25 at floor/wall and horizontal/vertical transitions.
Fit Elastoproof Collars into a wet coat; or form flanges with BRW PF Tape; or seal with RLA MAX SMP 25 and reinforce.
Clean, fill with RLA MAX SMP 25, then overlay with Elastoproof B50/BRW PF Tape/RLA Waterproofing Bandage.
Use blends to create fillets, fill voids, level rough asphalt/bitumen, or assist drying/coverage in cooler conditions.
Mortar: 3 parts sand : 1 part cement (by volume). Pre-wet to a workable mortar, then mix 1:1 (Gripset 51 : mortar) with an electric stirrer. Trowel/spatula to thickness.
Use the same 3:1 sand:cement mortar. Pre-wet, then blend 3:1 (Gripset 51 : mortar). Apply by brush/roller at specified coverage.
Apply Gripset 51 by brush or medium nap roller in two coats.
Apply at 750 µm wet film thickness (WFT). Work methodically; maintain uniform coverage.
Recoat after 2–4 hours (at 23 °C, 50% RH). Apply at 750 µm WFT perpendicular to the first coat. Target total DFT ≈1.0 mm (≈1.5 L/m² total).
Clean tools with water while wet. Dried product requires mechanical removal. Store sealed pails out of direct sun at room temperature; avoid freezing.
Record substrate condition, primer used, tape/band details, WFT readings per coat, recoat intervals and weather conditions.
WFT gauge readings logged by area; confirm target DFT ≈1.0 mm and coverage ≈1.5 L/m².
Confirm minimum 5 days before backfill and 10 days before flood testing at 23 °C/50% RH.
Wear protective gloves (nitrile or neoprene), safety glasses or goggles, and protective clothing to prevent skin contact. Avoid prolonged exposure to wet product.
Although solvent-free, ensure adequate ventilation in enclosed areas to control humidity and assist drying. Use fans or mechanical ventilation if necessary.
Non-flammable. Keep away from heat sources to maintain product integrity. Store sealed pails away from direct sunlight and freezing conditions.
Seek medical attention immediately in all cases of serious exposure.
Ensure surface is clean, sound, dry, and free from contaminants, laitance, curing compounds, moss, algae, and loose particles. Cure concrete for at least 28 days; render/screeds for at least 7 days. Fill voids and cracks with compatible repair mortar.
Prime with Gripset 51 diluted 1:3 (v/v) with clean water and apply liberally by brush or roller.
Gripset 51 (diluted)Sheets must be fixed in accordance with manufacturer’s recommendations. Ensure joints are flush and surface is clean, dry, and free of dust and loose materials.
Prime with Gripset 51 diluted 1:3 (v/v) with clean water before membrane application.
Gripset 51 (diluted)Ensure timber is clean, dry, structurally sound, and free from oils, stains, and surface coatings. Sand smooth and remove dust before priming.
Prime with Gripset 51 diluted 1:3 (v/v) with water.
Gripset 51 (diluted)Remove all surface oxidation, dirt, oil, and contaminants. Use a suitable degreaser, rinse, and dry thoroughly before priming.
Prime with Gripset 51 diluted 1:1 (v/v) with water, or apply Gripset OP Primer.
Gripset OP PrimerRemove all loose or unsound material and thoroughly clean surface. Ensure no standing water before priming.
Prime with Gripset 51 diluted 1:1 (v/v) with water for best adhesion.
Gripset 51 (diluted)Ensure panels are securely fixed and surface is clean, dry, and free from dust or debris.
Prime with Gripset 51 diluted 1:3 (v/v) with water if additional adhesion is desired.
Gripset 51 (diluted)