Skip to content
🚛 Flat Rate Shipping $15.95+ GST Australia-wide! Excludes rural/remote areas and bulky and heavy items. Online only. Learn More
🚛 Flat Rate Shipping $15.95+ GST Australia-wide! Excludes rural/remote areas and bulky and heavy items. Online only. Learn More
🚛 Flat Rate Shipping $15.95+ GST Australia-wide! Excludes rural/remote areas and bulky and heavy items. Online only. Learn More
🚛 Flat Rate Shipping $15.95+ GST Australia-wide! Excludes rural/remote areas and bulky and heavy items. Online only. Learn More
🚛 Flat Rate Shipping $15.95+ GST Australia-wide! Excludes rural/remote areas and bulky and heavy items. Online only. Learn More
🚛 Flat Rate Shipping $15.95+ GST Australia-wide! Excludes rural/remote areas and bulky and heavy items. Online only. Learn More
🚛 Flat Rate Shipping $15.95+ GST Australia-wide! Excludes rural/remote areas and bulky and heavy items. Online only. Learn More
🚛 Flat Rate Shipping $15.95+ GST Australia-wide! Excludes rural/remote areas and bulky and heavy items. Online only. Learn More
🚛 Flat Rate Shipping $15.95+ GST Australia-wide! Excludes rural/remote areas and bulky and heavy items. Online only. Learn More
🚛 Flat Rate Shipping $15.95+ GST Australia-wide! Excludes rural/remote areas and bulky and heavy items. Online only. Learn More
🚛 Flat Rate Shipping $15.95+ GST Australia-wide! Excludes rural/remote areas and bulky and heavy items. Online only. Learn More
🚛 Flat Rate Shipping $15.95+ GST Australia-wide! Excludes rural/remote areas and bulky and heavy items. Online only. Learn More
11

Adheseal Hi-Flex Construction Plus

Buy in Bulk and Save!

Price Per Unit: $10.90

Price Per Box: $9.81

High-build MS polymer hybrid sealant with primerless adhesion, +/-50% movement, UV/weather resistance and low-mess tooling. Ideal for perimeter glazing, cladding joints, precast expansion joints and general construction sealing/adhesion.
Vendor: Adheseal
SKU: HIFLEXCONPLUSGR/SSG
Availability: In Stock
$10.90
$10.90
Prices do not include GST
Physical Properties
Type of product: Hybrid ms polymer
Curing system: Moisture
Cure time: 2–3 mm per 24 hours at ~23–25°c, 50% rh
Density: 1.48 ± 0.05
Shore a hardness: 29 (after 14 days)
Joint movement capability: ±50%
Lap shear strength (astm c961): 0.65 mpa
Elongation to break (iso 37): >600%
Modulus @ 100% (astm d412): 0.41 mpa
Application temperature: +5°c to +40°c
Service temperature: -40°c to +100°c
Working time: ≈25 minutes @ 23°c & 50% rh
Skinning time: ≈10–15 minutes @ 23–25°c & 50% rh
% volatile by volume: <4%
Shelf life: 12 months (original packaging)
Storage conditions: Cool, dry, 10–35°c
Uv resistance: 500 h – good
Chemical resistance: Excellent to water & detergents; moderate to diluted acids/alkalis; petrol & oil short periods
Class (astm c920): Class 50
Colour options: White (9003), grey (7047), black (9011)
Packaging options: 600 ml sausage, carton of 20
Coverage examples (per 600 ml sausage): 6×6 mm: 16.7 m; 10×10 mm: 6.0 m; 12×12 mm: 4.2 m; 20×10 mm: 3.0 m; triangular 10×10 mm: 12 m
Paintability: Paintable (test first; non-flexible paints may crack)
Substrates: Masonry, concrete, brick, metals (excl. lead & copper), timber, plastics, stone, painted surfaces, rubber, fibreglass, porcelain, aluminium, powder coat, waterproof membranes
Limitations (summary): Not for long-term immersion, pools, aquariums, structural glazing, mirrors; avoid copper/brass discolouration; not for bituminous or epdm; avoid confined cure & mvtr
Shipping & Delivery

$15.95 + GST for Australia-wide shipping, excluding DG, oversized, long-length, and bagged items over 15kg. Rural, remote areas and site deliveries are also ineligible. If your order includes any of these, we will contact you to arrange additional freight fees. Online purchases only.

Use Hi-Flex Construction + for: perimeter window sealing; curtain walls; precast/tilt-up expansion joints; external wall & cladding joints; aluminium fabrication; lap seams; prefabricated concrete panels; display signs; automotive/marine bonding; general construction sealing.

Hi-Flex Construction +: A Technical Overview

Hi-Flex Construction + is a single-component, high-build MS polymer hybrid sealant that delivers primerless adhesion on most common construction substrates. The low-modulus formulation accommodates ±50% joint movement with excellent UV and weathering resistance, even in harsh Australian conditions. The Easy Tool – Low Mess formula guns smoothly and finishes cleanly, forming a permanent, elastic, dust-proof seal that resists bubbling in high humidity. Non-corrosive and low-VOC, it’s suitable for internal and external applications where reliability and clean presentation matter.
±50%
Joint Movement Capability (ASTM C920 Class 50)

Core Features & Specifications

  • MS Polymer Hybrid; single-component, high-build; low odour; low VOC.
  • Primerless adhesion to most non-porous substrates; strong bond on common building materials.
  • Movement capability ±50%; low modulus for stress relief in dynamic joints.
  • Excellent UV & weather resistance; non-staining, non-bleeding finish.
  • Cure rate ~2–3 mm/24 h (at 23–25°C, 50% RH); skin ~10–15 min; working time ~25 min.
  • Service temp −40°C to +100°C; application +5°C to +40°C.
  • Shore A ~29 (14 days); elongation >600% (ISO 37); modulus ~0.41 MPa @100% (ASTM D412).
  • Lap shear ~0.65 MPa (ASTM C961); UV resistance: 500 h – Good.
  • Colours: White (9003), Grey (7047), Black (9011); 600 ml sausages.

The Hi-Flex Construction + Advantage

  • Saves time: primerless on most non-porous substrates and easy tooling cuts clean-up and labour.
  • Fewer call-backs: elastic recovery and low modulus manage movement without cracking.
  • Site-tough: resists gassing/bubbling in humid conditions for a consistent finish.
  • Versatile: bonds/seals across metals, masonry, timber, plastics and coated substrates.
  • Professional finish: non-staining, paintable (test first; non-flexible paints may crack).

Proactive Troubleshooting

Scenario: Three-sided adhesion in facade joints

Potential Outcome: Restricted movement causes cohesive/adhesive failure or substrate stress.

Adheseal Best Practice: Use correct backer rod or bond-breaker tape to ensure two-sided adhesion per joint design guidance.

Scenario: Applying over dust, release agents or damp concrete

Potential Outcome: Poor adhesion and bubbling; premature failure.

Adheseal Best Practice: Clean using the two-wipe method with suitable solvent; ensure substrates are dry and concrete is cured (≥28 days) before application.

Applications in Practice: Trade Scenarios

For Builders (On-Site Applicator): Precast/Tilt-Up Expansion Joints

The Professional's Challenge

Movement and thermal cycling on exposed panels demand a flexible, UV-stable sealant that tools cleanly and stays put without primer delays.

The Adheseal Solution

Design joints at ~2:1 (width:depth). For 20 mm width, target ~10 mm depth with backer rod. Gun Hi-Flex Construction + and tool within 10–15 min for a smooth, elastic finish rated to ±50% movement.

Best Practice Note

Mask edges for crisp lines and remove tape before skin forms. Avoid trapping air while filling—continuous, steady bead prevents bubbles.

For Glaziers (Specifier/Installer): Perimeter Window Sealing

The Professional's Challenge

Modern facades require primerless bonding to powder-coated aluminium and glass with reliable UV stability and neat, low-mess presentation.

The Adheseal Solution

Lightly abrade non-porous frames, clean with appropriate surface prep, then apply a continuous bead and tool off for a weather-tight, non-staining seal that can be painted if required (test compatibility).

Best Practice Note

Maintain two-sided adhesion around frames by using bond-breaker tape on flat interfaces to allow thermal movement without stress.

For Fabricators (Business Owner/Operator): Aluminium & Panel Assembly

The Professional's Challenge

Need a clean, non-corrosive adhesive/sealant to bond dissimilar materials and manage differential movement with minimal rework.

The Adheseal Solution

Apply a triangular bead (nozzle cut at 90° then wedged) and compress parts to ≥2 mm final bond line. The low-modulus, high-elongation hybrid manages thermal mismatch without print-through.

Best Practice Note

For critical bonds, pre-treat metals and plastics as directed and verify adhesion with site pull tests before production runs.

Frequently Asked Questions

Do I need a primer on powder-coated aluminium or glazed tiles?

Usually no—Hi-Flex Construction + achieves strong primerless adhesion on many non-porous substrates. For critical or high-exposure applications, light abrasion and surface prep are recommended, with adhesion testing prior to installation.

What joint design should I use?

Aim for a ~2:1 width:depth ratio. Internal joints min 5 mm width/depth; external joints min 12 mm width. Use backer rod for joints >10 mm deep and avoid three-sided adhesion with bond-breaker tape.

Applications & Benefits

Applying Hi-Flex Construction +: Enhanced Protocols & Best Practices

  1. Surface Preparation

    Ensure substrates are structurally sound, clean, dry and free of dust, oils, release agents and moisture. Concrete must be cured ≥28 days.

    Two-Wipe Method

    Wipe with suitable solvent using a clean cloth; immediately follow with a second clean, dry wipe. Replace cloths frequently.

    Edge Masking

    Mask joint edges for neat lines; remove tape before skin forms.

    Timing: Maintain a clean, dry surface immediately prior to application to avoid re-contamination.
    Pro Tip: Lightly abrade non-porous substrates to increase surface energy and improve wet-out.
  2. Priming & Pre-Treatment

    Many non-porous substrates bond primerless after surface prep. For porous/critical joints, prime as specified and allow 30 min–2 h.

    Non-Porous

    Light abrasion then surface prep. Confirm with adhesion testing for critical works.

    Porous

    Apply primer by brush; allow to flash off (30 min–2 h) before sealing.

    Timing: Respect the 30 min–2 h window between pre-treatment/primer and sealant application.
    Pro Tip: Primers enhance long-term adhesion; they do not compensate for poor cleaning.
  3. Joint Design & Backer

    Target ~2:1 width:depth. Internal joints min 5 mm; external min 12 mm. Use backer rod for depth control; avoid three-sided adhesion with bond-breaker tape.

    Open-Cell Backer Rod

    Select rod ~25% larger than joint width; place to required depth.

    Closed-Cell Backer Rod

    Acceptable with care—do not damage the skin to avoid gassing.

    Timing: Install backer and mask before loading sausage gun to reduce delays.
    Pro Tip: Keep bond line to two faces only; use tape on flat interfaces.
  4. Application & Tooling

    Apply between +5°C and +40°C. Push the bead ahead of the nozzle to avoid air entrapment; fill completely and tool before skin forms (~10–15 min).

    Joint Sealing

    Cut nozzle at ~45° to joint width; maintain nozzle contact with both sides; tool with a moistened spatula.

    As Adhesive

    Cut nozzle at 90°; create triangular bead; assemble parts to ≥2 mm bond line.

    Timing: Skin 10–15 min; working time ~25 min at 23–25°C/50% RH.
    Pro Tip: Remove masking while sealant is still wet for the sharpest edges.

Limitations & Safety

Product Limitations

!
Not suitable for long-term water immersion or internal swimming pools; avoid high chlorine exposure.
!
Will not cure in totally confined spaces without access to atmospheric humidity.
!
Not for aquariums, mirror adhesion, or structural glazing.
!
May discolour copper & brass; not for bituminous, natural rubber, EPDM, or substrates that leach oils/plasticisers/solvents.
!
Avoid applying over substrates with active moisture vapour transmission or where air entrapment can occur (bubbling risk).

Safety & Handling Requirements

Personal Protective Equipment

Wear gloves and safety glasses during application and clean-up. Wash hands before eating, drinking or smoking. Launder contaminated clothing before reuse.

Ventilation

Use in well-ventilated areas. Avoid inhaling vapours. For confined or poorly ventilated spaces, increase airflow and limit exposure time.

Fire & Handling

Keep away from ignition sources when using solvents for clean-up. Store sealed in a cool, dry place (10–35°C).

Emergency First Aid
Eyes:
Hold open and rinse with water for ≥15 minutes. Seek medical advice.
Skin:
Wash with soap and water; rinse thoroughly.
Inhaled:
Move to fresh air; obtain medical attention if symptoms persist.
Swallowed:
Do not induce vomiting; seek medical advice immediately.

Seek medical attention immediately in all cases of serious exposure.

Limitations & Safety

Product Limitations

!
Not suitable for long-term water immersion (including pools/aquariums).
!
Not for structural glazing or mirror adhesion (use a dedicated mirror product after testing).
!
Avoid use on bituminous materials and natural/EPDM rubber; avoid fresh contact with solvents/alcohols during cure.
!
May discolour copper and brass — perform compatibility testing first.
!
Requires atmospheric humidity to cure — do not apply in totally confined spaces.

Safety & Handling Requirements

🧤
Personal Protective Equipment

Wear gloves and safety glasses. Wash hands before eating, drinking or smoking. Launder contaminated clothing before reuse.

🪟
Ventilation Requirements

Use in well-ventilated areas. Avoid vapour build-up; ensure adequate airflow for moisture-cure chemistry.

🔥
Fire & Handling Precautions

Keep ignition sources away when using solvents for cleaning. Observe storage conditions and shelf-life.

🚑
Emergency First Aid
Eyes:
Hold open; flush with water for ≥15 min. Seek medical advice.
Skin:
Wash with soap and water; remove contaminated clothing.
Inhaled:
Move to fresh air; obtain medical attention if symptoms persist.
Swallowed:
Do not induce vomiting. Seek medical advice immediately.

Seek medical attention immediately in all cases of serious exposure.

Hi-Flex Construction + Application Guide

Non-Porous Metals (Aluminium, Stainless, Galvanized, Powder Coat)

Lightly abrade with a fine abrasive pad; clean using appropriate surface prep with the two-wipe method. Ensure surfaces are dry and free from oil/contaminants.

Primer typically not required; use surface prep and confirm with adhesion test for critical works.

Allow 30 min–2 h between prep and application.

Adheseal 50A Surface Prep

Porous Substrates (Concrete, Renders, Mortars, Bricks)

Substrates must be sound, clean, dry and cured—concrete ≥28 days. Remove dust, laitance, curing agents and contaminants.

Primer recommended for optimal adhesion and durability in critical/high-exposure joints.

Brush apply primer; allow 30 min–2 h before sealing.

Everflex Supaprime

Plastics & PVC

Light abrasion then two-wipe clean. Verify compatibility; conduct adhesion tests.

Primer not typically required; confirm with testing for critical bonds.
Adheseal 50A Surface Prep
Adheseal Hi-Flex Construction Plus
Vendor: Adheseal
Adheseal Hi-Flex Construction Plus
$10.90
Vendor: Adheseal
Adheseal Hi-Flex Construction Plus
$10.90
Colour: Grey
Package Type: Single Buy

Alternative Products

Need Help with Adheseal Hi-Flex Construction Plus?

Need more information about this product? Hit the button below and reach out to one of our experts now.

Recently Viewed Products
Shop the look
Choose Options
Recently Viewed
Edit Option
Compare
Product applications, benefits, and relevant trades
Application / Use Case Key Benefit Primary Trades
Perimeter sealing of windowsPrimerless adhesion, clean tooling, UV stabilityGlaziers, Builders
Curtain walls & facade panelsLow modulus manages thermal movementGlaziers, Facade Contractors
Precast / tilt-up expansion joints±50% movement; durable weather sealBuilders